GENRAD 1864 PDF

Description The GenRad Megohmmeter is the choice for more demanding applications. The test voltage can be set to any value from 10 Vdc to Vdc in 1-volt steps and to Vdc in 10 volt steps. Thus the GenRad can be set to any common, or uncommon test voltage for ceramic, mica or paper capacitors, or other devices. The reverse resistance of rectifiers can be readily measured; the low test voltages are especially useful in measuring solid state diodes. In addition, no warm-up drift is encountered, and high zero stability is maintained during operation. Human engineering has not been overlooked in the GenRad Megohmmeter as evidenced by the warning light that is activated by the application of the test voltage.

Author:Zulujin Tujin
Country:Azerbaijan
Language:English (Spanish)
Genre:Art
Published (Last):28 April 2006
Pages:460
PDF File Size:8.56 Mb
ePub File Size:7.42 Mb
ISBN:180-2-14631-471-7
Downloads:94850
Price:Free* [*Free Regsitration Required]
Uploader:Moogukinos



Description The GenRad Megohmmeter is the choice for more demanding applications. The test voltage can be set to any value from 10 Vdc to Vdc in 1-volt steps and to Vdc in 10 volt steps. Thus the GenRad can be set to any common, or uncommon test voltage for ceramic, mica or paper capacitors, or other devices.

The reverse resistance of rectifiers can be readily measured; the low test voltages are especially useful in measuring solid state diodes. In addition, no warm-up drift is encountered, and high zero stability is maintained during operation. Human engineering has not been overlooked in the GenRad Megohmmeter as evidenced by the warning light that is activated by the application of the test voltage. The GenRad Megohmmeter is easy to use with direct-reading meter indication and lighted range switch that shows the multiplier for each range and voltage.

The maximum current possible at the terminals is limited to a 5mA and a panel light near the terminals warns when voltage is present. Stable power supplies and feedback voltmeter circuit minimize drift and time wasting adjustments. Guard and ground terminals permit measurement of grounded or ungrounded two- or three-terminal resistors. The instruments are supplied in a convenient, portable, Flip-Tilt case that is a stand for the meter in use and protects it in transit and storage Some GenRad Megohmmeter Applications Testing insulation resistance of wire and cables Boeing aircraft fuel pump inspection DC hydraulic pump motor assembly inspection Insulation resistance testing of relays, coils, sensors, controls and other electronic components Testing insulation resistance of cable harnesses and connectors.

ISPCONFIG 3 MANUAL PDF

GENRAD 1864 PDF

Shaktikazahn Send a Request To: The maximum current possible at the terminals is limited to a 5mA and a panel light near the terminals warns when voltage is present. We would also greatly appreciate it if you could provide us with this error code: The test voltage can be set to any value from 10 Vdc to Vdc in 1-volt steps and to Vdc in 10 volt steps. Send to a Friend. The reverse resistance of rectifiers can be readily measured; the low test voltages are especially useful in measuring solid state diodes. Full specifications can be found on the datasheet Resistance Accuracy: Stable power supplies and feedback voltmeter circuit minimize drift and time wasting adjustments. In-Stock Notification Request Sent Your request to be notified when this product is back in stock has been sent to our sales department.

VIENUOLIS KURIS PARDAVE FERRARI PDF

Stability of calibration in the GenRad Megohmmeter is maintained by use of a four-transistor unity gain amplifier. Stable power supplies and feedback voltmeter circuit minimize drift and time wasting adjustments. Safety has not been overlooked in the GenRad Megohmmeter as evidenced by the warning light that is activated by the application of the test voltage. The maximum current possible at the terminals is limited to a 5mA. The GenRad Megohmmeter is easy to use with direct-reading meter indication and lighted range switch that shows the multiplier for each range and voltage.

MANUAL CASIO FX 4200P PDF

Mazujinn The reverse resistance of rectifiers can be readily measured; the low test voltages are especially useful in measuring solid state diodes. This document contains the technical product manual and guidelines. This Megohmmeter has a test voltage which can be set between 10 to V in V steps and to volts in 10 V steps. You can send up to 10 dealer emails at a time, and up to 30 per day. Your Email Address Email is not vaild. Full specifications can be found on the datasheet Resistance Accuracy: Yes No Are you willing to prepay your order by check or wire transfer to avoid credit card fees? Send me a copy.

Related Articles